CaCl

Calcium Monochloride

Parameter 40Ca35Cl   X 2Σ 40Ca37Cl   X 2Σ Ref.
Y01  [MHz] 4563.7461(10) 4432.2607(10) 82012
Y11 [MHz] -23.9506(10) -22.9230(10)
Y21 [kHz] 34.46(12) 32.50(12)
Y02 [kHz] -3.0860(4) -2.9107(4)
Y12 [Hz] -0.80(45) -0.73(45)
γe [MHz] 42.208(30) 40.957(30)
αγ [MHz] -0.406(15) -0.389(15)
δγ [Hz] -55(8) -52(8)
µ0 [C · m]
     µ0 [D]
1.4227(10) x 10-29 
    4.265(3) a
 
µ1 [C · m]
     µ1 [D]
1.4280(3) x 10-29 
    4.281(1) a
 
µr [u] 18.6496602 19.2029400  
re [10-10 m] 2.4367580(4) b 2.4367562(4) b  

a From [84060]. Uncertainties are the statistical variation. Absolute uncertainty is ± 0.02 D.

b Recalculated as re = [505379.006(51) / µrY01]1/2 with units as given in table.


NIST Physical Measurement Laboratory National Institute of Standards and Technology NIST Physical Measurement Laboratory Back to the diatomic molecule selection page